A fridge freezer that has stopped is the one appliance failure with a clock attached, so the order here is deliberate: food first, diagnosis second.
After that, the single most useful thing you can establish is which failure you have, because "not working" covers three quite different situations.
Which of these is it?
- Completely dead — no light, no hum, no display.
- Running but not cold — you can hear it, the light works, but nothing is cooling.
- One compartment only — fridge warm, freezer fine, or the other way round. This is the most informative symptom of the three.
Completely dead
Start with the boring possibilities, because they are common.
- Is there power at the socket? Plug something else in. Fridge freezers are often on sockets behind the appliance that nobody has looked at in years.
- Has the plug fuse blown, or a breaker tripped?
- Is the plug fully in? Pushing an appliance back into a gap can lever a plug partly out of its socket.
- Is a switched spur or extension lead switched on?
- Is the appliance's own control set to off? Many have a thermostat position or a display setting that switches cooling off entirely, and it is easy to knock.
If there is power at the socket and the appliance is still dead, it is an internal electrical fault and needs an engineer.
Running but nothing is cold
The compressor is the pump that circulates refrigerant — the black cylinder at the back near the bottom. If the appliance hums and the compressor is warm, it is running.
Before assuming the worst, check three things.
The condenser coils. On many models these are the black grille on the back, and they shed heat. Coated in dust and pet hair, they cannot, and the appliance loses cooling capacity. Unplug it, pull it out and vacuum them. This is genuine, effective owner maintenance that almost nobody does, and it is free.
Ventilation. A fridge freezer needs an air gap around it, particularly above and behind. Built into a tight housing, or pushed hard against a wall, it cannot shed heat. Check the manual for the specified clearances.
Ambient temperature. Appliances have a climate class, and a fridge freezer in an unheated garage may stop working properly in winter — the fridge section relies on the thermostat sensing warmth, and in a cold garage it may never call for cooling, which leaves the freezer to thaw. If yours is in a garage or outbuilding, check whether it is rated for it.
If the coils are clean, ventilation is adequate, and it still will not cool, the likely causes are a failed compressor, a failed start relay, or a refrigerant leak. All are engineer territory, and all are worth a quote before committing, because a sealed-system repair is often uneconomic.
Only one compartment is cold
This is the useful symptom, because most fridge freezers cool both compartments from one source.
In a typical frost-free design there is one evaporator, usually in the freezer, and a fan that pushes cold air through a duct into the fridge. So:
- Freezer cold, fridge warm. Usually the air duct or the fan, not the cooling system. Common causes are a blocked duct, a failed evaporator fan, or a defrost fault that has let ice build up over the evaporator until it blocks the airflow. Listen for the fan with the door shut — many run only when the door is closed, so pressing the door switch in with a finger lets you hear whether it starts.
- Fridge cold, freezer warm. Less common and more likely to point at the thermostat, the defrost system or a control fault.
Frost building up in a thick layer where it should not is a strong clue — see a freezer not freezing, which covers defrost faults in detail.
Simple things that mimic a fault
- A door not sealing. Close the door on a piece of paper and pull. If it slides out with no resistance, the seal is not gripping at that point. Warm humid air leaking in causes frost build-up, constant running and poor cooling. Seals perish, and they are replaceable.
- A door left ajar, often by a drawer or a bottle pushed too far forward.
- Overfilling the fridge, which blocks the vents at the back of the compartment.
- Hot food put straight in, which raises the whole compartment.
- A recently moved appliance. If it has been laid on its side or back, oil can migrate out of the compressor. Manufacturers usually specify standing it upright for a period before switching it on — several hours at minimum, and the manual may say longer.
When to call an engineer
- There is power at the socket and the appliance is dead.
- It runs constantly and never gets cold, with clean coils and adequate ventilation.
- You can hear clicking every few minutes but the compressor does not start — often a failed start relay or overload protector, which is a small and relatively cheap part.
- There is a smell of hot electrics, or it trips the electrics — see tripping electrics.
Cover
Fridge freezers are the appliance where cover terms differ most, and two clauses are worth finding before you need them.
Food spoilage. Some policies include a contents allowance if a breakdown spoils the food; many do not, and those that do usually cap it and require a list or receipts. This is often the difference that justifies one policy over another.
Sealed system cover. The compressor and refrigerant circuit are the expensive part, and some policies exclude sealed-system faults altogether. A policy that covers everything except the compressor is not covering the thing most likely to write the appliance off.
See what each provider covers on our fridge freezer cover comparison.